Arming Monitors
System monitors are armed using a Monitor Arming Code
which identifies the alarm Display method (Single, Block, or
Dual monitors), Queuing method (Sequence or Hold), and the
Clearance method (Instant, Auto, or Manual clear). The
Monitor Arming Codes available in the AD1650B are listed at
the right, and are described in the Appendix, page A-4.
To arm a monitor:
1. Call the desired monitor to be armed.
2. Turn the keyswitch to the PROG position.
3. Select the Monitor Arming Code desired for that monitor
and enter the code number (1 - 15) on the keypad.
If a Dual display code is selected (13 - 15), when the first
(Hold) monitor is armed, the second (Sequence) monitor is
automatically selected (the next numeric system monitor)
and armed to the second Arm Type.
4. Press the ARM button in the keyboard Monitor group. The
Arm Type (see table at right) is displayed for five seconds,
in the on-screen Status Line, to verify the monitor arming.
For example: The Single/Sequence/Instant Clear arming code
was selected for the monitor by entering the number 1 on the
keyboard and pressing the Monitor ARM button. This
results in the on-screen display shown in Figure 3-1.
To disarm a monitor:
1. Call the monitor to disarm.
2. Turn the keyswitch to the PROG position.
3. Press the OFF button in the keyboard Monitor group.
To verify the monitor arming at any time, press the keyboard
ARM button. The Arm Type is displayed for five seconds in
the on-screen Status Line. If the monitor has not been armed
or has been disarmed, the “DIS” code is displayed.
Note: Monitor arming cannot be changed for any monitor if
any alarm contacts are active in the system.
Monitor Arming Codes
Code Description Arm Type
1 Single/Sequence/Instant Clear SSI
2 Single/Sequence/Auto (after 20 seconds) SSA
3 Single/Sequence/Manual (ACK key) SSM A*
4 Single/Hold/Instant Clear SHI
5 Single/Hold/Auto Clear SHA
6 Single/Hold/Manual Clear SHM A*
7 Block/Sequence/Instant Clear BSI
8 Block/Sequence/Auto Clear BSA
9 Block/Sequence/Manual Clear BSM A*
10 Block/Hold/Instant Clear BHI
11 Block/Hold/Auto Clear BHA
12 Block/Hold/Manual Clear BHM A*
First Monitor Second Mon
Arm Type Arm Type
13 Dual/Hold and Sequence/
Instant Clear DHI DSI
14 Dual/Hold and Sequence/
Auto Clear DHA DSA
15 Dual/Hold and Sequence/
Manual Clear DHM A* DSM A*
16 Disarm monitor DIS
* Manual Clear/Acknowledge is always enabled.
The Manual Clear/Acknowledge feature can be enabled or
disabled for any Instant or Auto Clear arming code. This must
be done after a monitor is armed with an arming codes. When
enabled, the letter “A” is displayed after the Arm Type in the
on-screen Status Line (e.g., SSI A). When disabled, the letter
“A” does not appear after the Arm Type.
To enable or disable Manual Clear for Instant or Auto:
1. Call the desired monitor.
2. Turn the keyswitch to the PROG position.
3. Enter one of the following code numbers on the keypad:
17 - to enable Manual Clear/Acknowledge
18 - to disable Manual Clear/Acknowledge
4. Press the Monitor ARM button.
Monitors can also be armed using the Monitor menu, page 4-
16. If a monitor block is desired, the Monitor menu must be
used to define all monitors within the block.
Refer to the Appendix, pages A-3 to A-7, for description of
Alarm Programming and Arming.
3-5