American Dynamics RJ1SNUD-1 Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Comutadores de rede American Dynamics RJ1SNUD-1. American Dynamics RJ1SNUD-1 Installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 10
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F
INSTALLATION GUIDE 1 of 10
SensorNet
Single-Position
Junction Box (J-Box)
Installation Guide
Figure 1. SensorNet J-Box
RJ1SNUD and RJ1SNUD-1 Series
This weather-tight box (Figure 1) provides Class 2
LPS power and data to the new SpeedDome Ultra
outdoor camera housing.
IMPORTANT: Read Regulatory Requirements
and other declarations on page 8.
© 2006 Sensormatic Electronics Corp.
IMPORTANT SAFEGUARDS
The J-Box is a 10A, 2-pole, ganged disconnect
device, which also provides short circuit and
overload protection, and has a minimum 3mm
open circuit clearance, in accordance with the
National Electric Code and applicable local codes
must be installed at a location readily accessible to
the equipment.
(Ein 10A, 2-poliges, gekoppeltes Ausschaltgerät,
welches auch über einen Kurzschluß- sowie
Überbelastungsschutz verfügt, und einen
minimum 3mm offenen Schaltabstand aufweist,
nach Übereinstimmung mit den Nationalen
Elektrischen Regelungen sowie lokalen Regeln,
muß an einem Standort installiert werden, welcher
einfachen Zugang zum Gerät erlaubt.)
Outside elements: To keep outside elements
from entering the J-Box, always mount it vertically
with cable exits facing down, and tighten the four
plastic screws.
Adding access holes to the enclosure: The
J-Box meets the NEMA 4 standard for
weatherproofing. To maintain this rating, make
sure any hole you drill in the enclosure is
thoroughly sealed with silicone-based RTV
compound.
Switching to 240Vac: If using 240Vac to drive the
J-Box, you must change jumper terminations on
the primary winding of transformer. Refer to label
inside cover of J-Box.
Approved power cords: Use only regulatory-
approved polarized power cords.
Socket-outlet: For installation using a line cord,
the socket-outlet must be installed near the
equipment and at an easily accessible location.
(Für Installationen mit einem Stromkabel muß die
Steckdose an einem Standort installiert werden,
welcher einfachen Zugang erlaubt.)
This product does not support Manchester
protocol: It will support SensorNet.
USE ONLY WITH American Dynamics products
and other approved products from
Sensormatic Electronics Corporation.
See inside for additional safeguards.
Access for Cables
from Host and Dome
Cover Retaining
Screws, Plastic (4)
Latches (2)
On/Off Switch
Spare
Fuses (2)
Vista de página 0
1 2 3 4 5 6 7 8 9 10

Resumo do Conteúdo

Página 1 - Junction Box (J-Box)

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 1 of 10 SensorNet Single-Position Junction Box (J-Box) Insta

Página 2 - J-Box Specifications

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 10 of 10 Declarations This product can only be used with Ame

Página 3 - Mounting the J-Box

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 2 of 10 SensorNet Single-Position J-Box Specifications REG I

Página 4 - Outdoor Pole Mounting

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 3 of 10 Mounting the J-Box This section explains how to mount

Página 5 - Connecting AC Power

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 4 of 10 Outdoor Pole Mounting Outdoor mounting (Figure 3) req

Página 6 - Data Cables

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 5 of 10 Connecting AC Power The J-Box comes wired for 120Vac

Página 7 - Testing for Power and Data

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 6 of 10 6. Run conduit and ac cable to box and clamp conduit

Página 8 - Removing the Transformer

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 7 of 10 Procedure 1. Turn power switch in J-Box to off (0).

Página 9 - Ordering Parts

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 8 of 10 Troubleshooting Problem Possible Solution No Power F

Página 10 - Declarations

SENSORNET SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-21, REV. F INSTALLATION GUIDE 9 of 10 Ordering Parts Only the following parts can be ordere

Comentários a estes Manuais

Sem comentários